Methods | Units | Conditions | Results | Requirements | Pass/Fail |
| Tensile properties
|
EN 12230
|
Mpa
|
New, 23°C | 0.54 | > 0.40
|
Pass |
| After A/W Ageing (1) | 0.55 | Pass | ||||
| After Spike Resistance ⑵ | 0.50 | Pass | ||||
| After A/W Ageing (1) + Spike Resistance (2) | 0.49 | Pass | ||||
| Variation
(%)
|
After Spike Resistance ⑵ | 7 | < 20
|
Pass | ||
| After A/W Ageing (1) +
Spike Resistance ⑵ |
11 | Pass | ||||
| Elongation at break
|
EN 12230
|
%
|
New, 23°C | 61 | > 40
|
Pass |
| After Ageing ⑴ | 52 | Pass | ||||
| After Spike Resistance ⑵ | 70 | Pass | ||||
| After A/W Ageing ⑴ + Spike Resistance ⑵ | 42 | Pass | ||||
| Variation
(%)
|
After Spike Resistance ⑵ | 15 | <20
|
Pass | ||
| After A/W Ageing (1) + Spike Resistance ⑵ | 19 | Pass | ||||
| Resistance to wear | EN ISO 5470-1 | g | New, 23°C | 2.8 | < 4.0 of mass loss between 500 and 1500 cycles | Pass |
| Water permeabilty | EN 12616 | mm/h | New, 23°C | > 2 000 | > 150 mm/h | Pass |
| Absolute thickness | EN 1969 (method A) | mm | New, 23°C | 13.0 | > 10 | Pass |
| Overall thickness | EN 1969 (method A) | mm | New, 23°C | 13.6 | - | - |
(1) A/ W ageing - Hot air ageing + hot water ageing
The hot air and water ageing is performed according to EN 13817 standard and immediately after according to EN 13744 standard. After surface exposure, the following properties are measured again to check any potential change:
Shock absorption
Tensile properties / Elongation at break
(2) Spike resistance
The spike resistance test is performed according to test method described in the EN 14810 standard.